How Much Attic Ventilation Is Enough
Much of the debate stems from the tremendous variation in climate across north america.
How much attic ventilation is enough. Allows cool dry air to enter the attic. So if your attic is 1 500 sq. In other words the entire vent opening doesn t count as vented space. The following product options will allow you to achieve an intake nfva of 528 square inches.
That said air resistance and interference such as vent grates reduces the area of true ventilation. Is ridge vent alone sufficient for proper ventilation in your attic. In order to facilitate this exchange of warm and cool air the general rule of thumb suggests installing at least 1 sq. This results in a constant upward air movement due to the buoyancy of warmer air.
The basic formula for a typical residence is 1 foot of passive vent opening per every 150 square feet of attic size. Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca. To keep air flowing your roof needs just the right amount of attic ventilation. Attic ventilation keeps the air moving and stops mold from growing but too much ventilation can be just as bad as having none.
Ft you divide that by 150 to get 10 sq. Before we explore how to ventilate an attic space it is prudent to understand how much ventilation is needed. But what type works best and how do you know when enough is enough. The rule of thumb on the amount of vent space needed is approximately 1 sq.
Throughout the roofing industry there is a widespread lack of agreement over adequate attic ventilation. Ideally the total vent space should be equally divided between lower soffit vents and upper vents at the roof peak. Ventsure inflow intake vent. Most building codes require a ratio of 1 150 ventilation space to attic floor space.
Do not use gable vents because it s possible to draw rain and snow into the attic. Of vent space for every 150 sq. Choose one of the following products to meet the recommended intake nfva of 528 square inches. The uniform building code requires that the amount of venting area in the attic be equal to 1 150 of the area of the floor and in most circumstances it allows a ratio of 1 300 if the venting area.
How much attic ventilation is enough. We hear this question quite often from zimmerman exteriors customers. This characteristic of air may be used to help create a flow of air ventilating the attic. Generally speaking you need a ratio of 1 300 where for every 300 square feet of ceiling space you need 1 square foot of attic ventilation.